Rinnai Boiler: Central heating common components

Updated · by Aurora Star Tech Inc.

Central heating common components on a Rinnai boiler: Parts the central heating loop needs around the boiler. Sizing and ratings are as listed in the manual.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Central heating loop components

How to fix central heating common components: step by step

  1. Size the expansion tank and charge it to 2 PSI (14 kPa) below the cold system pressure. Consult the tank maker for sizing when replacing it.
  2. Fit an air separator on the central heating supply side.
  3. Use the boiler control panel to read system pressure and temperature, which alternate on the display. An external gauge port is on the Primary-Secondary Heating Kit.
  4. Install a relief valve directly on the supply side of the boiler. Use the 30 PSI valve supplied with the boiler, or a 3/4 in valve in the 30 to 45 PSI range. The Primary-Secondary Heating Kit has a port for the central heating relief valve.
  5. Run the boiler only in a pressurized closed-loop heating system that is free of air and impurities.
  6. Install a water fill valve to hold proper pressure in the central heating circuit.
  7. Use a backflow preventer in the fill circuit where local code requires it.
  8. Install a dirt trap to protect the boiler from debris in the plumbing.
  9. Do not adjust or service the internal low water cut-off, which is a factory-installed pressure sensor type.
  10. If an external low water cut-off is required by local code, mount its probe above the minimum safe water level and wire it to the matching terminal on the boiler PC board.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 58. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977