Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Boiler: Annual maintenance checklist

Updated · by Aurora Star Tech Inc.

Annual maintenance checklist on a Rinnai boiler: Yearly service checks for the boiler. Vent and screens, fan and motor, controller, pressure, relief valve, dirt trap, DHW filter, expansion tank, condensate trap and drain. Fan motors are permanently lubricated and do not need oil. Clean the controller with a soft damp cloth only, no solvents. Pressure relief valve test must be done only by a licensed professional because the discharge is scalding.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All I-Series Plus condensing combi boilers

How to fix annual maintenance checklist: step by step

  1. Inspect the vent system for blockages or damage. Clean the vent screen or room air filter if used.
  2. Clean dust and dirt from the fan and motor.
  3. Clean the controller with a soft damp cloth.
  4. Confirm the system pressure is between 17 and 26 PSI. If low, add water until it is in range.
  5. Operate the pressure relief valve manually once a year with safe discharge.
  6. Close the shutoff valves under the boiler, clean the heating system dirt trap, then purge the air.
  7. If DHW flow drops, close the DHW shutoff valves and clean the DHW inlet filter.
  8. Perform expansion tank checks as the manufacturer recommends.
  9. Check the condensate trap for sediment. Unplug the bottom, remove sediment, and replace the plug. Do not use a wrench on the condensate drain.
  10. Confirm the condensate drain is not blocked and the condensate pump (if used) works.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 120. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977