Navien Boiler: Zone pump wiring for up to four zones
Zone pump wiring for up to four zones on a Navien boiler: Wiring notes for running up to four zone pumps from the boiler. Each zone output is rated for a maximum of 2.5 A.
Applies to: NCB700 multi-zone wiring
How to fix zone pump wiring for up to four zones: step by step
- Use dry-contact zone pump connections when the thermostats are not powered by 24 VAC.
- Use the 24 VAC thermostat inputs when the thermostats supply their own 24 VAC.
- Connect each zone pump to its line and neutral. Keep each pump at or below 2.5 A.
- Connect the zone 4 pump wire to the recirculation pump connection, if zone 4 is used.
- Connect the system pump on the air handler setup to the boiler pump terminals, at 2.5 A maximum, with ground.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 57-61. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.