Navien Boiler: Zone pump wiring – thermostats with 24VAC power
Zone pump wiring - thermostats with 24VAC power on a Navien boiler: Dry contact zone pump connections where the thermostats supply 24VAC power, with zone pumps 1 to 4 and the boiler internal pump.
Applies to: NCB700 zone pump systems
How to fix zone pump wiring - thermostats with 24vac power: step by step
- Connect each thermostat input to its 24 VAC line and neutral.
- Connect zone pumps 1 to 4 to their line and neutral (each max 2.5 A).
- Connect the boiler internal pump (max 2.5 A) to line and neutral.
- Connect pump ground to the ground terminal.
If the unit shows an error code, look it up: Navien Boiler codes
Source: NCB700 Installation & Operation Manual, p. 52. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.