Navien Boiler: Wiring zone valves with 24 VAC powered thermostats

Updated · by Aurora Star Tech Inc.

Wiring zone valves with 24 VAC powered thermostats on a Navien boiler: Same zone valve layout, with thermostats powered by 24 VAC. The boiler's internal 24 V transformer (75 VA) powers the zone valves, LWCO switches and thermostat terminals.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 boilers with zone valves

How to fix wiring zone valves with 24 vac powered thermostats: step by step

  1. Connect zone valves 1 to 3 with NO/NC/COM as in the zone valve layout.
  2. Connect each thermostat to its 24 VAC line and neutral terminals.
  3. Check the total zone valve load does not exceed 72 VA; otherwise add an external zone valve controller.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 214. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.