Navien Boiler: Vent installation detector limits

Updated · by Aurora Star Tech Inc.

Vent installation detector limits on a Navien boiler: The vent installation detector only checks that the pipe is inserted to 70 mm in the exhaust collar. It does not detect leaks, pipe separation past the collar, blocked vents, vent movement, or a worn or stuck switch. Do not rely on it as a carbon monoxide alarm or safety switch. Inspect all vent joints regularly.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 vent installation detector

How to fix vent installation detector limits: step by step

  1. Inspect all vent joints at regular intervals.
  2. Do not rely on the detector to find leaks, separated joints or blockages.
  3. Use a carbon monoxide detector as a separate safeguard.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

More other tips for boiler

Source: Navien NCB700 installation and operation manual, p. 235-237. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.