Navien Boiler: Run a space heating pipe air purge
Run a space heating pipe air purge on a Navien boiler: Air purge mode bleeds air from the space heating pipe.
Applies to: NCB700 series
How to fix run a space heating pipe air purge: step by step
- Press Back and Menu together for 3 seconds.
- Select 8. Air Purge Mode.
- Press the Command dial to run the SH pipe air purge.
- Boiler returns to normal mode if no input for 15 minutes.
If the unit shows an error code, look it up: Navien Boiler codes
More button combinations tips for boiler
Source: Navien NCB700 installation and operation manual, p. 134. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.