Navien Boiler: Removing cascade communication settings

Updated · by Aurora Star Tech Inc.

Removing cascade communication settings on a Navien boiler: Returns the water heaters to independent operation.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 cascade system

How to fix removing cascade communication settings: step by step

  1. On the main NCB700 panel, press Back and Menu together for 3 seconds, then select 4. Cascade Status and Set.
  2. Select 2. Cascade System Removal.
  3. Select YES.
  4. The water heaters revert to independent operation.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 88. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.