Navien Boiler: Install the Common Vent Collar Kit on the boiler
Install the Common Vent Collar Kit on the boiler on a Navien boiler: The collar kit has a backdraft damper that blocks flue gas and cold air when the fan is off. It also has a maintenance port for checking the damper plate.
Applies to: NCB700 with Navien Common Vent Collar Kit
How to fix install the common vent collar kit on the boiler: step by step
- Remove the screws from the exhaust vent adapter.
- Open the front cover.
- Detach the exhaust vent adapter from the top of the unit.
- Disconnect the Vent Installation Detector (VID) wiring from the harness.
- Connect the Common Vent Collar Kit to the exhaust duct of the boiler.
- Use the maintenance port to check the damper plate condition. Maintenance steps are in section 9.9, which is not on these pages.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 Installation & Operation Manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.