Navien Boiler: Gas conversion kit location and gas pipe sizing notes

Updated · by Aurora Star Tech Inc.

Gas conversion kit location and gas pipe sizing notes on a Navien boiler: The Propane Gas & High Altitude Conversion Kit is inside the cabinet. Gas connection fitting on all boilers is 3/4 in. Boiler should be the first appliance downstream of the gas meter.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 all models

How to fix gas conversion kit location and gas pipe sizing notes: step by step

  1. Remove the front cover to access the conversion kit.
  2. Confirm the gas meter capacity is at least the total capacity of connected appliances.
  3. Use 1/2 in rigid pipe only within the sizing table limits; do not use 1/2 in corrugated connectors or tubing.
  4. Keep flexible lines free of crimps and tight bends.
  5. Install a union on the gas line close to the boiler for service.
  6. Check the EFV minimum and maximum flow rating before installing an excess flow valve.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

More other tips for boiler

Source: NCB700 Installation & Operation Manual, p. 54-55. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.