Navien Boiler: Force a special operation mode
Force a special operation mode on a Navien boiler: Special operation modes hold the boiler in a fixed operating state for testing.
Applies to: NCB700 series
How to fix force a special operation mode: step by step
- Press Back and Menu together for 3 seconds.
- Select 7. Special Operations.
- Choose a mode: Normal, 1st MIN, DHW 1st MAX, 2nd MIN, DHW 2nd MAX, SH 1st MAX or SH 2nd MAX.
- Boiler returns to Normal mode after 3 hours with no input.
If the unit shows an error code, look it up: Navien Boiler codes
More service & test modes tips for boiler
Source: Navien NCB700 installation and operation manual, p. 134. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.