Navien Boiler: External recirculation with HotButton or aquastat and dedicated return
External recirculation with HotButton or aquastat and dedicated return on a Navien boiler: Dedicated return DHW recirculation controlled either by a HotButton push button or by an aquastat, not both.
Applies to: NCB700 DHW recirculation
How to fix external recirculation with hotbutton or aquastat and dedicated return: step by step
- For HotButton mode, install HotButton push button(s) and a recirculation pump, with no aquastat.
- For aquastat mode, install an aquastat and a recirculation pump, with no HotButton.
- For aquastat mode, connect the aquastat to terminal CNIN5 on the PCB.
- Set the aquastat below 140 °F (60 °C), the maximum DHW set temperature of the NCB700.
- HotButton push buttons and wall plates are sold separately.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.