Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Boiler: Enter Special Operations and select SH 2nd MAX

Updated · by Aurora Star Tech Inc.

Enter Special Operations and select SH 2nd MAX on a Navien boiler: Used to run the boiler at space heating second maximum, for example to purge gas from the supply line during pressure checks.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 series

How to fix enter special operations and select sh 2nd max: step by step

  1. Press Back and Menu together for 3 seconds.
  2. Turn the Command dial to 7. Special Operations.
  3. Press the Command dial to enter special operation mode.
  4. Turn the Command dial to 7. SH 2nd MAX and press it to select.
  5. Press Back twice to return to normal operation.
  6. Run space heating; leave on until the boiler shuts down from lack of gas, then turn it off.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

More service & test modes tips for boiler

Source: Navien NCB700 installation and operation manual, p. 58. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.