Navien Boiler: Enter special operation mode 7 (SH 2nd MAX)
Enter special operation mode 7 (SH 2nd MAX) on a Navien boiler: Special operation mode 7 runs the boiler at its second-stage space heating maximum. It is used during gas pressure testing. Exit it with the Back button.
Applies to: NCB700 front panel
How to fix enter special operation mode 7 (sh 2nd max): step by step
- Press the Back button and the Menu button together for 3 seconds.
- Turn the dial to '7. Special Operations' and press the dial.
- Turn the dial to '7. SH 2nd MAX (CL 2e MAX)' and press the dial to select it.
- Press the Back button twice to return to normal mode.
If the unit shows an error code, look it up: Navien Boiler codes
More service & test modes tips for boiler
Source: Navien NCB700 installation & operation manual, p. 228. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.