Updated · by Aurora Star Tech Inc.

DHW piping guidelines on a Navien boiler: Use only fittings and components approved for potable water. Keep hot water piping short. Do not add pressure control valves, flow restrictors or mechanical mixing valves on the direct DHW line unless local code requires them.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 DHW piping

How to fix dhw piping guidelines: step by step

  1. Use only potable-water approved pipe, fittings, valves and solder.
  2. Tighten connections carefully to avoid damage.
  3. Fit unions and manual shut-offs on domestic cold and hot lines.
  4. Keep the hot water run as short as practical.
  5. Insulate DHW supply and recirculation lines if applicable. Do not cover drains or the relief valve.
  6. After installation, clean the cold water inlet filter, test DHW supply and check for leaks.
  7. Tell the owner the inlet filter must be cleaned periodically.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.