Navien Boiler: Derating at high altitude
Derating at high altitude on a Navien boiler: Above 2,000 ft the boiler derates about 3% per 1,000 ft on natural gas and 4% or more per 1,000 ft on propane. Above 5,400 ft on NG, change to the high altitude orifice.
Applies to: NCB700 high altitude installs up to 10,100 ft
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 142. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.