Navien Boiler: Connecting Ready-Link communication cables
Connecting Ready-Link communication cables on a Navien boiler: Connect the cascade units with Ready-Link cables. All units must be powered off before connecting.
Applies to: NCB700 cascade with NPE-A2 or NPE-S2 water heaters
How to fix connecting ready-link communication cables: step by step
- Make sure power is off to all units.
- Connect the Ready-Link cables to the CNK1 terminal strip on the NCB700.
- Connect the Ready-Link cables to the J6 ports on the left side of the front panel of each NPE-A2 water heater.
- Restore power to the boiler and turn all boilers on with the Power button.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 87. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.