Navien Boiler: Cascade system roles and operating rules

Updated · by Aurora Star Tech Inc.

Cascade system roles and operating rules on a Navien boiler: Cascade system with one NCB700 combi-boiler and up to 15 Navien NPE-A2 or NPE-S2 water heaters.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 main unit with NPE-A2 or NPE-S2 sub units

How to fix cascade system roles and operating rules: step by step

  1. Set the NCB700 as the main unit. It controls the on/off state of all sub units.
  2. Set each NPE sub unit to DHW only. Only the main unit provides space heating.
  3. Make all setting changes at the main unit. Changes made on sub units are ignored.
  4. Configure each unit for cascade operation.
  5. After saving cascade settings, turn the boiler and all water heaters off, then back on for the changes to take effect.
  6. Sub units start in stages to meet DHW demand once the main unit turns them on.
  7. If an error occurs in a cascade, the error shows on the display of the unit that failed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.