Navien Air Conditioner: Sensor and valve functions on the outdoor unit

Updated · by Aurora Star Tech Inc.

Sensor and valve functions on the outdoor unit on a Navien air conditioner: Quick reference for what each outdoor sensor and valve is used for. T3 is the outdoor coil temperature, used for high-temperature protection and outdoor fan control. T4 is the outdoor ambient temperature, used to limit maximum compressor frequency. T5 is the compressor discharge temperature, used for high-discharge and low-superheat protection. T7 is the control board pipe temperature, used for condensation prevention. Tfin is the IPM (inverter module) temperature, used for high IPM temperature protection. PT is the pressure transducer, which senses evaporating pressure and is used for compressor frequency control and low-pressure protection. The pressure equalizer valve (PEV) balances system pressure before compressor start-up.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NAA outdoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Air Conditioner codes

Source: Navien NAA air conditioner service manual, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.