Viessmann Boiler: Underfloor heating high-temperature protection
Underfloor heating high-temperature protection on a Viessmann boiler: Underfloor loops are damaged by high water temperature, so an extra aquastat is needed to stop the pump and boiler if the loop overheats.
Applies to: Vitocrossal 300 CU3A with underfloor heating
How to fix underfloor heating high-temperature protection: step by step
- Install an immersion or strap-on aquastat in the low-temperature underfloor loop, downstream of the mixing valve.
- Set it to de-energize the pump and/or boiler when the loop overheats.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
2635455794125160199CU3ACU3A 26CU3A 35CU3A 45CU3A 57CU3A 94CU3A 125CU3A 160CU3A 199Vitocrossal 300, type CT3
Source: Viessmann Vitocrossal 300 CU3A installation manual, p. 43. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.