Viessmann Boiler: Reading the Vitodens boiler nomenclature

Updated · by Aurora Star Tech Inc.

Reading the Vitodens boiler nomenclature on a Viessmann boiler: The model code is built from segments. The boiler segment is shown first (VD = Vitodens). The next digit gives the series (1 = 100 series, 2 = 200 series). The domestic hot water capability follows (X = no DHW, I = indirect DHW, C = on-demand DHW, T = stratified loading tank). The page also shows the heating circuit and zone counts, the number of boilers and supply temperatures, and how the system is zoned (ZP = pumps, ZV = zone valves, TV = thermostatic radiator valves, C = combination).

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200 / 222-F nomenclature

How to fix reading the vitodens boiler nomenclature: step by step

  1. Read the boiler segment (VD = Vitodens) and the series digit (2 = 200 series).
  2. Read the domestic hot water letter (X, I, C or T) to confirm the DHW type.
  3. Read the circuit codes (HC = heating circuit, ZC = zone circuit, HC/ZC = combination) and the number of circuits.
  4. Read the zoning code (ZP, ZV, TV or C) to confirm how the system is zoned.
  5. Check the drawing version and the number of boilers and supply temperatures in the code against the job drawings.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125

More other tips for boiler

Source: Vitodens 222-F B2TB Application Guide, p. 7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.