Viessmann Boiler: Reading and acknowledging fault messages
Reading and acknowledging fault messages on a Viessmann boiler: When a fault occurs, the fault symbol and red fault indicator flash and Fault appears. Note the cause and fault code before calling the heating contractor. Repeated acknowledgement in quick succession is dangerous; a repeating fault must be reported.
Applies to: Vitocrossal 300 CU3A with Vitotronic 200 KW6B
How to fix reading and acknowledging fault messages: step by step
- Press OK to see the cause of the fault.
- Press the info button to see system performance and measures you can take first.
- Write down the cause and the fault code, for example Outside temp sens 18 and Fault A2.
- Acknowledge the fault by following the menu prompts. The message then moves to the menu.
- Do not acknowledge fault messages several times in quick succession.
- If a fault repeats, notify the heating contractor so the cause can be analysed.
- To view an acknowledged fault later, open the extended menu and choose Fault.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
CU3I 2ZC2ZP.01CU3I 3HC/Z3ZP.01CU3X 1ZC1ZP.01Vitocrossal 300 CU3A 26Vitocrossal 300 CU3A 35Vitocrossal 300 CU3A 45Vitocrossal 300 CU3A 57Vitocrossal 300 CU3A 94Vitocrossal 300 CU3A 125Vitocrossal 300 CU3A 160Vitocrossal 300 CU3A 199
Source: Vitocrossal 300 CU3A operating instructions, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.