Viessmann Boiler: Oxygen diffusion barrier tubing
Oxygen diffusion barrier tubing on a Viessmann boiler: Underfloor plastic tubing without an oxygen diffusion barrier causes corrosion. The warranty does not cover resulting leaks.
Applies to: Underfloor heating loops
How to fix oxygen diffusion barrier tubing: step by step
- Separate non-barrier underfloor tubing from the boiler with a heat exchanger.
- Use oxygen diffusion barrier tubing where possible.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitorond 100, VR1 Technical Data, p. 11. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.