Viessmann Boiler: Outdoor reset override restrictions
Outdoor reset override restrictions on a Viessmann boiler: The outdoor reset energy saving feature has an override meant mainly for an external energy management system. The override may only be used if one of the listed conditions is true.
Applies to: Vitorond 100 with Hydrostat or outdoor reset module
How to fix outdoor reset override restrictions: step by step
- Use the override only if an external energy management system lowers boiler water temperature as heating load falls.
- Or use it only if the boiler is not used for any space heating.
- Or use it only if the boiler is part of a modular or multiple boiler system with total input of 300,000 Btu/h or more.
- Or use it only if the boiler is equipped with a tankless coil.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Viessmann Vitorond 100 installation and service manual, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.