Viessmann Boiler: Open coding level 2
Open coding level 2 on a Viessmann boiler: Coding level 2 gives access to every coding address, including the level 1 codes. Enter it from the normal display with the two-step button sequence below.
Applies to: Vitotronic 200-H HK1B
How to fix open coding level 2: step by step
- Press OK together with the second button shown in the manual and hold for about 4 seconds.
- Press OK together with the same button again and hold for about 4 seconds.
- Confirm that the display shows 'Coding level 2'.
- Choose the group you need: General, DHW, Solar, Heating circuit 1/2/3, or All codes standard unit.
- Select the coding address, pick the value from the table and confirm with OK.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
More access & passwords tips for boiler
Source: Vitotronic 200-H, HK1B Installation and Service, p. 54. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.