Viessmann Boiler: Holiday program (energy saving for central heating)
Holiday program (energy saving for central heating) on a Viessmann boiler: Lowers central heating to the reduced room temperature for the length of an absence. DHW heating is switched off during the holiday, with DHW tank frost protection still active. The program starts at 00:00 on the day after departure and ends at 00:00 on the day of return, so the time program runs on the departure and return days. It applies to all heating circuits. Heating circuits set to 'Only DHW' get no central heating and only boiler and DHW tank frost protection. The set dates can be checked under Information.
Applies to: Vitocrossal 300 CU3A
How to fix holiday program (energy saving for central heating): step by step
- Open the extended menu.
- Select 'Heating'.
- Select 'Holiday program'.
- Enter the departure and return dates.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
2635455794125160199CU3ACU3A 26CU3A 35CU3A 45CU3A 57CU3A 94CU3A 125CU3A 160CU3A 199Vitocrossal 300, type CT3
More settings shortcuts tips for boiler
Source: Viessmann Vitocrossal 300 CU3A operating instructions, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.