Viessmann Boiler: Heating circuit pump OFF setting can freeze pipes
Heating circuit pump OFF setting can freeze pipes on a Viessmann boiler: A pump switch-off threshold set below 34°F (1°C) can let pipes outside the heated envelope freeze. Consider standby periods such as holidays.
Applies to: Vitotronic 300 GW6B heating circuit pump
How to fix heating circuit pump off setting can freeze pipes: step by step
- Check the outdoor temperature threshold in coding a3 before leaving the system in standby.
- Do not set a3 below 1°C unless the piping is protected.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitotronic 300 GW6B installation and service manual, p. 111. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.