Updated · by Aurora Star Tech Inc.

Flue gas test point on a Viessmann boiler: Create a flue gas test point on the vent pipe for combustion testing. The printed hole size is partly unreadable; 10 mm is the value shown.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitorond 200 VD2 flue test point

How to fix flue gas test point: step by step

  1. Drill a 10 mm hole on the side of the vent pipe.
  2. Place the hole about two to three times the vent pipe diameter away from the boiler flue gas collar.
  3. Seal and insulate the vent pipe after drilling.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More commissioning tips for boiler

Source: Vitorond 200 VD2 installation manual, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.