Viessmann Boiler: Enter coding 2 (general, pump, LON and fault settings)
Enter coding 2 (general, pump, LON and fault settings) on a Viessmann boiler: Coding 2 covers the remaining addresses. Addresses are scrolled in sequence: system circuit A1 first, then mixing valve circuits M2 and M3.
Applies to: Vitocontrol-S VD2/CT3/CM2 coding 2
How to fix enter coding 2 (general, pump, lon and fault settings): step by step
- Press the w key and the rw key together for about 2 seconds, then confirm.
- Select the required address with the up or down key. The address flashes.
- Confirm. The value flashes.
- Change the value with the up or down key and confirm. 'Adopted' shows briefly.
- To view more addresses, use the up or down key.
- Press the w key and the rw key together for about 1 second to leave coding.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
300-K MW1Vitocontrol-S, VD2/CT3/CM2, 300-K MW1
More service & test modes tips for boiler
Source: Vitotronic 100 GC1 / Vitocontrol-S VD2/CT3/CM2 installation and service instructions, p. 167. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.