Viessmann Boiler: Combustion fault through pulsation (no fault display)
Combustion fault through pulsation (no fault display) on a Viessmann boiler: Burner pulsates or runs noisy, with no fault code shown.
Applies to: Vitocrossal 200 CM2
Common causes of combustion fault through pulsation (no fault display)
- Excessive gas input
- Insufficient or excessive air
- Condensate build-up in the flue system
- Incorrect flue outlet
- Thermo-acoustic or combustion noise
- Incorrect CO2 settings
How to fix combustion fault through pulsation (no fault display): step by step
- Adjust gas input to the rated boiler heating output.
- Check the condensate drain.
- Check the flue outlet and flue system.
- Adjust the burner per p. 15.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
186246311CM2 186 burnerCM2 246 burnerCM2 311 burnerVitocrossal 200 CM2 186Vitocrossal 200 CM2 246Vitocrossal 200 CM2 311Vitocrossal 200 CM2 400Vitocrossal 200 CM2 500Vitocrossal 200 CM2 620Vitocrossal 200 CM2 620 TX
Source: Vitocrossal 200 CM2 186 to 311 Service Instructions, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.