Viessmann Boiler: Boiler location and flue gas system
Boiler location and flue gas system on a Viessmann boiler: The boiler is a direct vent appliance and can be installed for sealed combustion regardless of room size or ventilation. It can go in living areas, unventilated utility rooms, cupboards, closets, alcoves with no combustible clearance, and attics with a direct outlet for the flue. Use the Viessmann PPS concentric flue system for sealed combustion or side wall venting, certified with the boiler. Vertical venting is possible with AL29-4C single-wall room-air-dependent venting (UL listed Category IV). See the Venting System Installation Instructions for details.
Applies to: Vitodens 222-F, B2TB 68 and 125
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
222-F B2TB 19222-F B2TB 35222-F B2TB 68222-F B2TB 125B2TB 19B2TB 35B2TB 68B2TB 125VD2T 1HC1T4ZP.01VD2T 1HC1T4ZV.01Vitodens 222-F, B2TB 19Vitodens 222-F, B2TB 35Vitodens 222-F, B2TB 68Vitodens 222-F, B2TB 125
Source: Vitodens 222-F B2TB application guide, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.