Viessmann Heat Pump: Read the Screen 1 live data columns
Read the Screen 1 live data columns on a Viessmann heat pump: Screen 1 updates once per second. The column order is fixed, so read the sensor and output values in that order when checking the unit.
Applies to: Vitocal 100-WA
How to fix read the screen 1 live data columns: step by step
- Check column 2 for the operating state (H, H RL, H RM, H MP).
- Check SH and EEV for superheat and expansion valve position.
- Check HP and LP (psi) for high and low side pressure.
- Check CL, CH, FC, HW, AR, AS, LI and LO for compressor, freeze, tank, air and loop temperatures.
- Check column 17 (LFL) for gas percentage or a sensor error code.
- Check C, F and W for compressor, fan and water speed in percent of full speed.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
More service & test modes tips for heat pump
Source: Vitocal 100-WA installation, service and operating instructions, p. 46-47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.