Viessmann Heat Pump: Installation rules for A2L refrigerant rooms
Installation rules for A2L refrigerant rooms on a Viessmann heat pump: Rules for ignition sources and room size where A2L refrigerant appliances are installed or ducted.
Applies to: Vitocal 100-WA
How to fix installation rules for a2l refrigerant rooms: step by step
- If the room is smaller than the minimum area (Amin) or has an effective dispersal volume below the minimum, keep the room free of continuously operating open flames and other potential ignition sources.
- A flame-producing device may stay in the same space only if it has an effective flame arrest.
- Confirm a leak detection system is installed. The unit must stay powered except during service.
- Use non-sparking tools for A2L refrigerants and check for leaks with a refrigerant detector before and during installation.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: vitocal_100-wa_ap1t_ios.pdf, pp. 6-7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.