Viessmann Heat Pump: Connect to the control board terminal and reach the installer screen
Connect to the control board terminal and reach the installer screen on a Viessmann heat pump: The setup and monitoring screens are reached through a terminal session with the control board in the junction box. The installer screen is password protected.
Applies to: Vitocal 100-WA control board
How to fix connect to the control board terminal and reach the installer screen: step by step
- Connect a Mini-B USB cable from the control board to a computer or tablet.
- Open PuTTY and set the baud rate to 250000, 8N1.
- Press 1 for Screen 1 (live data) or 2 for Screen 2 (configuration).
- On Screen 2, use the cursor keys or w, a, s, d to move, and + and - to change values.
- Press $ to open the password prompt, then enter 1010 for the installer section.
- Press h on any screen for help, and Escape to return to Screen 1 or 2.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
More access & passwords tips for heat pump
Source: Vitocal 100-WA installation, service and operating instructions, p. 46-47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.