Carrier Heat Pump: Wiring scenario 2 (default): wired controller with RS485
Wiring scenario 2 (default): wired controller with RS485 on a Carrier heat pump: Default method. The wired controller communicates over RS485 with the indoor and outdoor units.
Applies to: Wired controller and indoor/outdoor wiring
How to fix wiring scenario 2 (default): wired controller with rs485: step by step
- Do not use any 24 V terminals on the indoor or outdoor unit.
- Connect the Ha and Hb terminals on the wired controller to the Ha and Hb terminals on the indoor display board.
- Use 16 AWG shielded stranded wire for the controller connection.
- Wire the indoor and outdoor communication as shown in Fig. 31.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK
Source: D5CURA installation manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.