Carrier Heat Pump: Preparing and flaring refrigerant pipe
Preparing and flaring refrigerant pipe on a Carrier heat pump: Cut, deburr and flare each pipe end before connecting to the units.
Applies to: Field copper refrigerant piping
Common causes of preparing and flaring refrigerant pipe
- Burrs or an uneven cut can cause leaks at the flare.
- A deformed or dented pipe loses heating efficiency.
How to fix preparing and flaring refrigerant pipe: step by step
- Measure the distance between the indoor and outdoor units.
- Cut the pipe a little longer than that distance, square at 90°. Do not dent or deform it.
- Remove all burrs with a reamer or deburring tool, holding the pipe pointing down.
- Seal the pipe ends with PVC tape while preparing them.
- Sheathe the pipe in insulation.
- Slide the factory flare nut on the correct way round before flaring. It cannot be turned after flaring.
- Remove the tape, clamp the flare block so the pipe end sticks out past the form, and flare with the tool to the Table 9 dimensions.
- Remove the tool and block, and check the flare for cracks and an even surface.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK
Source: Carrier D5CURA installation manual, p. 13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.