Updated · by Aurora Star Tech Inc.

Set DHW temperature range before adjusting on a Viessmann boiler: The DHW setpoint is 50 to 140 F / 10 to 60 C by default. Coding 56:1 extends it to 50 to 203 F / 10 to 95 C. Observe the maximum DHW temperature and adjust the high limit before raising the range.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DHW temperature setpoint, coding 56

How to fix set dhw temperature range before adjusting: step by step

  1. Check the maximum allowed domestic hot water temperature.
  2. Set coding 56:1 only if a higher range is needed.
  3. Adjust the adjustable high limit to match.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B

More commissioning tips for boiler

Source: Vitotronic 200 KW2 service instructions, p. 53, p. 55. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.