Viessmann Boiler: Example: boiler set-point boost after switching to normal room temperature (FA:20, Fb:30)
Example: boiler set-point boost after switching to normal room temperature (FA:20, Fb:30) on a Viessmann boiler: When operation changes from reduced to normal room temperature, the boiler set-point is raised by a percentage for a set time. Example: boiler set-point from the heating curve is 50°C / 122°F; with FA 20% it becomes 60°C / 146°F and is held for 60 minutes (Fb 30 steps at 2 minutes each).
Applies to: Vitotronic 200-H, Model HK1M
How to fix example: boiler set-point boost after switching to normal room temperature (fa:20, fb:30): step by step
- Confirm FA (raise %) and Fb (duration) values in Coding 2.
- Note the boiler set-point from the heating curve at the time of the switch.
- Verify the raised set-point holds for the coded duration before it returns to the curve.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
HK1BHK1MHK1SHK3SVitotrol 200Vitotrol 300
Source: Vitotronic 200-H installation and service instructions, p. 50. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.