Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Mini-Split: Remove the electrical control box and main control board (09K/12K/18K)

Updated · by Aurora Star Tech Inc.

Remove the electrical control box and main control board (09K/12K/18K) on a Carrier mini-split: Anti-static gloves must be worn. Disconnect power before starting.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 09K/12K/18K size

How to fix remove the electrical control box and main control board (09k/12k/18k): step by step

  1. Remove the 2 screws holding the electronic control box and the 2 screws of the earth wire.
  2. Disconnect the temperature sensor, pump, fan motor and water level switch connectors.
  3. Lift out the electronic control box subassembly.
  4. Release the 3 clasps of the main control board and remove the 1 earth wire screw.
  5. Remove the main control board subassembly.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Mini-Split codes

More other tips for mini-split

Source: D5FSCAH / D5FLCAH service manual, p. 57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.