Carrier Mini-Split: Read-only inquiry codes
Read-only inquiry codes on a Carrier mini-split: These codes show values only and cannot be changed. 6 = compressor target frequency; 7 = compressor run frequency; 9 = unit voltage; 10 = capacity test (special use); 11 = not available; 14 = indoor fan speed (multiply display number by 8 for RPM); 15 = relative humidity (units with RH sensor only); 16 = setpoint compensation temperature; 17 = dust concentration (not used); 18 = Wi-Fi signal strength in dBm, shown as 0 to 4 (4 is strongest). Codes 19 and 27 to 30 show not available.
Applies to: Indoor unit / remote inquiry
How to fix read-only inquiry codes: step by step
- Enter Inquiry Mode and scroll to the code.
- Read the value on the display and convert as noted above.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK
More service & test modes tips for mini-split
Source: Carrier D5FSFAH service manual, p. 17-19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.