Carrier Mini-Split: Indoor unit mounting height for flammable refrigerant
Indoor unit mounting height for flammable refrigerant on a Carrier mini-split: The indoor unit must be mounted at least 5.9 ft (1.8 m) above the floor. The room area must meet the minimum in the room area table for the charge.
Applies to: Indoor unit installation
How to fix indoor unit mounting height for flammable refrigerant: step by step
- Mount the indoor unit at least 5.9 ft (1.8 m) above the floor.
- Check the charge against the room area table for the measured centre height.
- Correct the minimum area for altitude if needed.
If the unit shows an error code, look it up: Carrier Mini-Split codes
Models
45MBCAQ12XA3D5FLCAH36XAKD5FLCAH48XAKD5FSCAH12XAKD5FSCAH18XAKD5FSCAH24XAK
More commissioning tips for mini-split
Source: D5FSCAH / D5FLCAH service manual, p. 4. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.