Viessmann Heat Pump: Zero crossing detection error
Zero crossing detection error on a Viessmann heat pump: If the zero crossing signal interval is wrong for 240 seconds continuously, the unit stops and the LED shows the failure. The correct interval is 6 to 13 ms.
Applies to: DLCURA outdoor unit
Common causes of zero crossing detection error
- Zero crossing signal interval outside 6 to 13 ms
How to fix zero crossing detection error: step by step
- Check the power supply waveform and wiring to the zero crossing input.
- Confirm the signal interval is between 6 and 13 ms.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: DLCURA Service Manual, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.