Viessmann Heat Pump: Remove the compressor
Remove the compressor on a Viessmann heat pump: WARNING: Evacuate the system and confirm there is no refrigerant left before removing the four-way valve or compressor. For R32 and R290, recover refrigerant, flush with nitrogen, then repeat both steps before heating brazed parts. Only professionals should do this work.
Applies to: DLCURA 18 to 60 outdoor units
How to fix remove the compressor: step by step
- Remove the flange nut and the terminal cover.
- Disconnect the compressor connectors.
- Remove the hex nuts and washers that secure the compressor to the bottom plate.
- Heat the brazed joints and remove the discharge pipe and suction pipe.
- Lift the compressor off the base pan with pliers.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: DLCURA Service Manual, p. 77-78. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.