Viessmann Heat Pump: Remove IPM module board and 24V board (48K-58K)
Remove IPM module board and 24V board (48K-58K) on a Viessmann heat pump: Continues electrical parts removal. DC fan motors connect to the main control board. Compressor wires are removed here.
Applies to: 48K-58K
How to fix remove ipm module board and 24v board (48k-58k): step by step
- Remove the 2 screws and disconnect the power supply wires.
- Remove the 3 screws and disconnect the wires connected to the compressor.
- Remove the 3 screws and remove the radiator.
- Disconnect the wires between the IPM module board and the main control board.
- Remove the 4 screws, release the 4 hooks, and remove the IPM module board.
- Remove the 1 screw, disconnect the wires, and remove the 24V board.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: DLCLRC service manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.