Viessmann Heat Pump: Outdoor unit panel removal, sizes 24K to 36K (208/230V)
Outdoor unit panel removal, sizes 24K to 36K (208/230V) on a Viessmann heat pump: Order of panel removal for the 24K to 36K outdoor units. Photos are for reference and may differ from the actual unit.
Applies to: DLCSRB sizes 24K, 30K and 36K (208/230V)
How to fix outdoor unit panel removal, sizes 24k to 36k (208/230v): step by step
- Turn off the air conditioner and the power breaker.
- Remove the handle screws (2) and take off the handle.
- Remove the top cover screws (4); two are under the handle. Lift off the top cover.
- Remove the front right panel screws (2) and take off the front right panel.
- Remove the front panel screws (9) and take off the front panel.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: Viessmann DLCSRB service manual, p. 62-63. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.