Viessmann Heat Pump: Compressor check
Compressor check on a Viessmann heat pump: Checks the compressor windings for balance.
Applies to: DLCSRB outdoor units, sizes 06 to 36
How to fix compressor check: step by step
- Disconnect the compressor.
- Measure the resistance between U-V, V-W and U-W.
- All three values should be equal. If they are not, the compressor is faulty and must be replaced.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: Viessmann Vitocal 100-S DLCSRB service manual, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.