Carrier Heat Pump: Remove electric auxiliary heat module (optional)

Updated · by Aurora Star Tech Inc.

Remove electric auxiliary heat module (optional) on a Carrier heat pump: Removes the optional electric auxiliary heat module and its fuse. Disconnect power and lock out before starting. Quantity of modules per model is listed in the setting table for this section.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FUAA with optional EHKMB auxiliary heat module

How to fix remove electric auxiliary heat module (optional): step by step

  1. Remove the 2 screws from the upper cover plate assembly and remove the plate.
  2. Remove the 3 fixing screws.
  3. Pull out the auxiliary heat module.
  4. Use needle-nose pliers to pull the wire connected to the fuse.
  5. Loosen the retaining nut and remove the fuse.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Source: Carrier D5FUAA service manual, p. 50-51. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.