Carrier Heat Pump: 485 communication fault between indoor and outdoor units (S1, S2)

Updated · by Aurora Star Tech Inc.

485 communication fault between indoor and outdoor units (S1, S2) on a Carrier heat pump: Troubleshooting for the 485 communication link on the S1 and S2 signal wires. Parts to have ready: signal wires, magnet ring, indoor PCB, outdoor PCB. The flowchart on the page is not fully clear, so steps follow the logical order of the checks shown.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FUAA

Common causes of 485 communication fault between indoor and outdoor units (s1, s2)

  • Broken signal wire
  • Signal wire not shielded or shield not grounded
  • Electrical interference from nearby lamps or power transformers
  • Signal wire too long
  • Signal wires not inserted properly on the PCB
  • Faulty indoor main PCB
  • Faulty outdoor main PCB

How to fix 485 communication fault between indoor and outdoor units (s1, s2): step by step

  1. Check whether the signal wire is broken and replace it if needed.
  2. Check whether the signal wire is shielded cable and whether the shield is grounded. Use shielded cable and ground the shield if not.
  3. Check for interference, such as too many lamps or power transformers, or a signal wire that is too long. Remove the interference or add a magnet ring on the power wire.
  4. Check that the signal wires are fully inserted on the PCB. Pull out and reinsert them.
  5. Power off, then restart the unit 2 minutes later.
  6. If the error persists, replace the indoor main PCB.
  7. If the error still persists, replace the outdoor main PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Source: Carrier D5FUAA service manual, p. 41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.