Viessmann Air Handler: UV LED output (CN43) 24 VAC
UV LED output (CN43) 24 VAC on a Viessmann air handler: Provides 24 VAC through a relay that closes while the fan runs. It can power a compatible UV LED light or a pilot relay with a 24 VAC coil to control other equipment.
Applies to: Main board CN43 UV LED terminal
How to fix uv led output (cn43) 24 vac: step by step
- Connect a compatible UV LED or a 24 VAC pilot relay coil to CN43.
- Confirm the load is compatible with 24 VAC output.
If the unit shows an error code, look it up: Viessmann Air Handler codes
Models
DLFLABH36XA3DLFLABH48XA3DLFLABH60XA3DLFSABH18XB3DLFSABH24XB3DLFSABH30XB3DLFSABH36XB3DLFUAAQ18XB3DLFUAAQ24XB3DLFUAAQ30XB3DLFUAAQ36XA3DLFUAAQ36XB3DLFUAAQ48XA3DLFUAAQ60XA3
More other tips for air handler
Source: DLFSAB and DLFLAB Service Manual, p. 4. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.