Viessmann Air Handler: Power feed and auxiliary heater circuit
Power feed and auxiliary heater circuit on a Viessmann air handler: Outdoor unit supplies main power to the indoor unit, so turning off the outdoor unit also removes indoor power. No indoor-side disconnect is needed on the link wiring; a 3-pole disconnect may be added for extra protection. The electric auxiliary heater needs its own branch circuit with a field-supplied disconnect within sight of and readily accessible from the unit. Do not connect it to the indoor unit breaker.
Applies to: DLFSAB / DLFLAB with electric auxiliary heater
How to fix power feed and auxiliary heater circuit: step by step
- Isolate the outdoor unit power when the indoor unit must be de-energised.
- Use a separate branch circuit with a disconnect for the auxiliary heater, within sight of the unit.
- Do not connect the auxiliary heater to the indoor unit circuit breaker.
If the unit shows an error code, look it up: Viessmann Air Handler codes
Models
DLFLABH36XA3DLFLABH48XA3DLFLABH60XA3DLFSABH18XB3DLFSABH24XB3DLFSABH30XB3DLFSABH36XB3DLFUAAQ18XB3DLFUAAQ24XB3DLFUAAQ30XB3DLFUAAQ36XA3DLFUAAQ36XB3DLFUAAQ48XA3DLFUAAQ60XA3
More other tips for air handler
Source: Vitocal IND-A DLFSAB/DLFLAB service manual, p. 9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.